Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Eng. sanit. ambient ; 25(1): 107-114, jan.-fev. 2020. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1090122

ABSTRACT

RESUMO Com a escassez da disponibilidade de água doce e o aumento da demanda de água no mundo e no Brasil, uma das alternativas são os sistemas de dessalinização de água, que removem os sais das águas salobra ou salgada. Este estudo teve como objetivo avaliar a eficiência de um sistema piloto de dessalinização de água salobra a qual foi obtida a partir da mistura de águas do mar e de rio até atingir concentração de sólidos dissolvidos totais (SDT) de 1.500 mg.L-1. O sistema piloto de dessalinização, com capacidade de 1,0 m3.h-1, é composto de ultrafiltração (UF) e abrandamento como pré-tratamento à osmose reversa (OR). Foram realizadas análises de qualidade da água na entrada e saída das unidades de tratamento relativas a SDT, condutividade elétrica, turbidez, pH, cor aparente, alcalinidade, dureza total, cálcio, magnésio, cloreto, sulfato e temperatura. Foram avaliadas a pressão osmótica, o fluxo de filtração e a taxa de recuperação de água no sistema de OR. Com os resultados obtidos, conclui-se que a eficiência de remoção de SDT e condutividade foi de 99%. A UF foi eficiente na remoção de turbidez, enquanto a OR apresentou maiores eficiências de remoção de sais. O sistema piloto de tratamento foi capaz de remover todos os parâmetros estudados. A taxa de recuperação na OR foi de 74,64%.


ABSTRACT Considering the shortage of fresh water availability and an increased demand for water in the world, including Brazil, one of the alternatives for water supply are water desalination systems, which remove salts from brackish or seawater. The objective of this study was to evaluate the efficiency of pilot water desalination system treating brackish water which was obtained mixing fresh water and seawater up to reach 1,500 mg L-1 of total dissolved solids (TDS) concentration. The pilot desalination plant with production capacity of 1.0 m3 h-1 is composed of ultrafiltration (UF) and softener working as a pre-treatment to reverse osmosis (RO). Experiments were performed to analyze some water quality parameters as TDS, electrical conductivity, turbidity, pH, apparent color, alkalinity, total hardness, calcium, magnesium, chlorides, sulfates, and temperature. Osmotic pressure, filtration flow and water recovery rate were also measured for the RO. Analyzing the result obtained, it can be concluded that the efficiency of TDS removal and conductivity were 99%. UF was efficient in removing turbidity, whereas RO reached higher salt removal efficiencies. The pilot plant system could remove all water quality parameters studied. Recovery rate in RO was 74.64%.

2.
Eng. sanit. ambient ; 24(4): 809-819, jul.-ago. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1039777

ABSTRACT

ABSTRACT Constructed wetlands might be an alternative for communities away from urban centers and not served by a domestic wastewater treatment system. The purpose of this study was to provide instructions for the implementation of subsurface flow constructed wetland systems. To that end, we gathered information regarding the construction aspect, plants, and operational parameters used in systems which already operate in the country and the respective efficiency of these sets after previous treatment. The system in real scale proposed by Oliveira et al. (2005) was prominent among those that presented the highest efficiency. It was preceded by upflow anaerobic reactor built in brick, with macrophyte of the Typha genre, crushed stone at the entry and exit of the system, and sand in its intermediate portion. It required 1.04 m² surface area per inhabitant in humid temperate climate and hot summer, 1.71 m³ d-1 flow, and one-day hydraulic detention. The considerations presented here might help the construction of this kind of system, regarding dimensional and operational criteria.


RESUMO As wetlands construídas podem ser uma alternativa para comunidades afastadas de centros urbanos que não são atendidas por rede de tratamento de esgoto. Visando à orientação para implantação do sistema de wetlands construídas de fluxo subsuperficial, foi levantada uma série de informações a respeito dos aspectos construtivos, das plantas e parâmetros operacionais utilizados em sistemas já em funcionamento no país e a respectiva eficiência do conjunto, após um tratamento precedente. Entre os sistemas que apresentaram melhor eficiência, destacou-se o de Oliveira et al. (2005) em escala real, precedido por reator anaeróbio de fluxo ascendente, construído em alvenaria, com a macrófita do gênero Typha, brita na entrada e saída do sistema e areia na parte intermediária, com uma área superficial de 1,04 m2 por habitante de clima temperado úmido com verão quente, vazão de 1,71 m3 d-1 e tempo de detenção hidráulica de um dia. A elaboração das considerações apresentadas neste trabalho pode auxiliar na construção desse tipo de sistema, construído nos critérios de dimensionamento e operação.

SELECTION OF CITATIONS